КРОВЛЯ / ОБЛИЦОВКА / СТАЛЬ

How to Specify Self-Drilling Screws: Drill Point, Length and Purlin Thickness

📅 2026-11-10 · Build Fastener

Three numbers decide the fastener

A self-drilling screw is specified by diameter, length and drill point. Everything else - coating, head, washer - is selected after those three are right. Get them wrong and no amount of coating quality will save the fixing.

Step 1: match the drill point to the steel

The drill point is the small tapered tip that drills the hole before the thread engages. Its size determines the maximum total steel thickness it can pass through in one operation.

Drill pointTypical capacityUsed for
No. 1up to about 1.6 mmthin sheet, light cladding
No. 2up to about 2.0 mm0.5-1.0 mm sheet to thin purlin
No. 3up to about 5.8 mmsheet plus standard purlin
No. 5up to about 12.5 mmheavy purlin, thick built-up sections

Two failure modes follow a mismatch. If the point is too small, the operator pushes harder, the tip overheats, the coating burns and the point dulls - the screw either stalls or breaks. If the point is too large for thin sheet, the hole is oversize and the thread has nothing to bite.

Step 2: build the length from the actual stack

The length is not the sheet thickness. It is the sum of every layer the screw passes through before it reaches the purlin, plus the engagement in the purlin.

  1. Roof sheet thickness (0.5 mm, 0.6 mm, 0.8 mm are common).
  2. Insulation thickness after compression - not the nominal thickness. Mineral wool typically compresses 20-30 percent under the washer.
  3. Any spacer, bracket or separating layer.
  4. Purlin wall thickness, plus at least three full threads of engagement.

A screw that only just reaches the purlin will hold until the first wind event. A screw that is far too long will bottom out, deform the sheet and leave the washer under-compressed, which is the more common leak path.

Step 3: check the crest and valley geometry

On trapezoidal sheet, crest fixing and valley fixing are different specifications, not different habits.

  • Crest fixing: the screw passes through the top of the profile, so the effective stack includes the profile height. A long screw is normal here, and a large-diameter washer is used to spread the load across the crest.
  • Valley fixing: the screw sits in the trough, so the stack is thinner. Using a crest-length screw in a valley will over-compress the washer or hit the purlin web at an angle.
  • Side lap and stitching: a smaller-diameter screw is used to pull two sheets together. It is not a structural fixing and must not be substituted for one.

What the drawing should show

A specification drawing is adequate when it states: screw diameter and length, drill point number, coating class, washer type, fixing position (crest, valley, clip, stitch), and the torque or tool setting used on site. Without the fixing position, the length cannot be verified; without the tool setting, the washer compression cannot be repeated.

Installation parameters that protect the specification

The most common cause of site failure is not the screw - it is the driver. Recommended practice is a consistent tool setting: roughly 1,600-2,500 rpm, 400-600 W, and light axial pressure of about 15-25 kg. The screw should be driven perpendicular to the sheet, and pressure should be released once the point has drilled through, letting the thread form and seat the washer naturally.

A washer that is visibly flattened beyond its original thickness has been over-driven. A washer that still shows a gap has not been compressed enough to seal. Both are visible in a five-second inspection, which makes them the cheapest quality check on the roof.

Запросить