DACH / FASSADE / STAHL

Steel Building and Metal Roofing

Self-drilling screws and structural bolts for steel buildings and metal roofing.

METAL ROOF FIXING POSITIONS

Start with the connection point

A steel roof uses several distinct screw connections. Select each one from the roof profile, sheet build-up, support thickness and system detail.

01 / EXPOSED FIXING

Crest fixing

Fastens the roof sheet through its rib into the purlin.

Hex washer head self-drilling screw fixing through the crest of a profiled metal roof sheet into the steel purlin, with T1 and T2 grip dimensions
User-supplied photograph of a hex washer head self-drilling screw with bonded sealing washer
SCREW FAMILYHex washer head self-drilling screw

Hex washer head with a bonded EPDM washer. Grip length must cover the rib height plus any compressed insulation; effective length must reach the rib, the insulation and the purlin together. The Buildex 26 crest range runs 50-125 mm for fixing thicknesses of 22-111 mm.

View screw detailsCyclone washer option
02 / EXPOSED FIXING

Valley fixing

Fastens through the pan of the roof sheet into the purlin.

Hex washer head self-drilling screw fixing through the flat valley pan of a profiled metal roof sheet into the steel support
User-supplied photograph of a hex washer head self-drilling screw with bonded sealing washer
SCREW FAMILYHex washer head self-drilling screw

At the valley the grip length stays within the sheet thickness and the effective length covers the sheet plus the purlin. Buildex 26 valley lengths: 20 mm to 6 mm and under, 30 mm to 16 mm and under, 38 mm to 24 mm and under, 45 mm to 31 mm and under.

View screw details
03 / CONCEALED SYSTEM

Clip fixing

Fastens the concealed roof clip to the purlin beneath the standing seam.

Screw fixing a concealed standing seam roof clip to the steel support below the folded seam
Pan head self-drilling screws for bracket and clip fixing
SCREW FAMILYPan head self-drilling screw

A pan head screw without a sealing washer, because the membrane or sheet is not penetrated at the seam. Length follows the clip base plus support thickness: 16 mm for under 5 mm, 22 mm for under 12 mm, 30 mm for under 20 mm and 40 mm for under 30 mm in the Buildex 26 bracket range.

View screw details
04 / SHEET-TO-SHEET

Side-lap stitching

Connects overlapping sheets between their primary support fixings.

Stitching screw fastening the overlapping side lap of adjacent profiled metal roof sheets
Hex washer head side-lap stitching self-drilling screw with bonded EPDM sealing washer, shown on a white background
SCREW FAMILYRoofing side-lap stitching screw

A short 20 mm stitching screw with an EPDM washer covers a sheet-to-sheet build-up of 6 mm and under. Spacing comes from the panel detail; stitching screws do not replace the primary sheet-to-purlin fixings.

View screw details

Screw length selection by fixing position

Three lengths are involved and they are not interchangeable, and the check changes with the roof build-up. A roof without insulation is checked against the profile height alone. A roof with insulation has to carry the compressed insulation thickness as well, which moves both the grip length and the effective length up.

Screw selection without insulation

Section through a roof sheet fixed to a steel purlin without insulation, showing the sheet profile height and the purlin or batten thickness that grip length and effective length are measured against
  • Grip length (GL) must be equal to or shorter than the profile height.
  • Effective length (EL) must be equal to or longer than the profile height and the purlin or batten thickness combined.

Screw selection with insulation

Section through an insulated roof build-up showing the compressed insulation thickness between the roof sheet and the purlin, which adds to both the grip length and the effective length
  • Grip length (GL) must be equal to or shorter than the profile height and the compressed insulation thickness combined.
  • Effective length (EL) must be equal to or longer than the profile height, the purlin or batten thickness and the compressed insulation thickness combined.

Screw length selection

Screw length terms on one screw: overall length from the tip to the underside of the head, grip length clamping the fixed materials, and effective length of the thread embedded in the base material
  • Length (L) is the overall length of the screw from the tip to the underside of the head.
  • Grip length (GL) is the portion of the screw that penetrates and clamps the materials being fastened.
  • Effective length (EL) is the threaded portion that embeds in the base material and provides the holding power.
  • Fixing thickness (T) ≤ effective length (EL). T is the total build-up clamped at the fixing position, sheet plus any compressed insulation plus the purlin or batten, and it must never exceed the effective length, otherwise the thread runs out before it reaches the support.

On hex, wafer and smooth top heads the catalogue length is measured from underneath the head; on bugle, ribbed countersunk and decking heads it is measured over the top of the head.

Published length and fixing-thickness ranges, ITW Buildex 26 catalogue pages 35-42
Fixing position Screw reference (Buildex 26 range) Length L Fixing thickness covered
Crest fixing5.5 mm / 12g, 6.5 mm drilling capabilityHex washer head, EPDM 10.5 mm washer50 mm22-36 mm
55 mm28-41 mm
68 mm34-54 mm
75 mm34-61 mm
95 mm50-81 mm
110 mm55-96 mm
125 mm68-111 mm
Valley fixing5.5 mm / 12g, 6.5 mm drilling capabilityHex washer head, EPDM 10.5 mm washer20 mm6 mm and under
30 mm16 mm and under
38 mm24 mm and under
45 mm31 mm and under
Bracket and clip fixing4.8 mm / 10g, 4.5 mm drilling capabilityPan head, no sealing washer16 mmunder 5 mm
22 mmunder 12 mm
30 mmunder 20 mm
40 mmunder 30 mm
Side-lap stitching6.8 mm / 15g, 2.4 mm drilling capabilityHex washer head, EPDM 10.5 mm washer20 mm6 mm and under
Thick purlin fixing12.5 mm drilling capabilityHex washer head, EPDM 10.5 mm washer38 mmunder 16 mm
50 mm28 mm and under
70 mm18-46 mm
Thick purlin fixing20 mm drilling capabilityHex washer head, EPDM 10.5 mm washer60 mm28 mm and under

Fixing thickness is the total build-up the screw clamps at that position: sheet thickness plus any compressed insulation plus the purlin or batten. Worked check for a crest fixing: a 28 mm rib with a 60 mm purlin needs an effective length of at least 88 mm, so 95 mm is the first crest length that covers it. Adding 40 mm of compressed insulation takes the requirement to a 68 mm grip and a 128 mm effective length, beyond the 125 mm crest length, so that detail moves to a thick purlin variant or a changed build-up.

Metal roof and wall details contain several different connections: roof sheet to purlin, side-lap stitching, flashing and bracket attachment, and the structural frame. Identify the connection before selecting a fastener.

Start with the roof detail

Record the panel profile, material and thickness; the supporting steel grade and thickness; insulation, spacers and any air gap; and the fixing position. Use the engineer or panel supplier fastening schedule for edge, corner and internal zones.

Profiled galvanized metal roof sheets meeting under a ridge cap, showing the panel profile, rib spacing and the ridge fixing line on both sides

Match the screw to the substrate

  • Use a self-drilling screw only within the tested range of its exact point, diameter, steel grade and installation conditions.
  • Treat self-tapping screws as a different selection: establish the pilot-hole requirement and effective thread engagement.
  • Where a stainless-body bi-metal screw is specified, check its joined hardened point, drilling result, coating and washer assembly.

Check the washer and fixing position

Crest, valley, side-lap and concealed-clip details have different bearing and sealing needs. Match the washer profile and backing to the panel and screw head. Stitching screws connect overlapping sheets; they do not replace the primary sheet-to-support fixing.

Installation and seating

Screw length is set by the fixing position rather than by the screw alone: grip length must cover the parts being clamped and effective length must reach into the purlin. Use the position table above for crest, valley, clip and side-lap details, then confirm the length datum and the length table of the offered product.

Approve the proposed bit, speed and seating on a representative build-up; remove drilling swarf and inspect the seal. Confirm the washer compresses against the panel without over-driving and that the point has passed through the support by the required amount.

Structural bolts are a separate connection

Hexagon bolts for frame joints are selected by the drawing, material or property class, dimensions and compatible nuts and washers. A dimensional bolt reference alone does not qualify an assembly for preloaded or slip-critical structural use. Follow the engineer-approved assembly procedure.

Information for a specification or quotation

  • Roof section, panel profile, material and thickness
  • Support grade and thickness, insulation and spacers
  • Fixing position and design or panel-supplier fastening schedule
  • Exposure, coating, washer and required test or approval evidence
  • Product drawing, quantity, destination and packing requirements

Need fasteners for your project?

Anfragen

Ähnliche Produkte

Frequently asked questions

How should screw length be selected for a roof-sheet fixing?

Record the panel profile, connected layers, support and selected product variant. Follow the panel or roof-system detail and the product instructions for the length datum and support engagement; do not infer these from sheet thickness alone.

How do I select a coating for an exposed roof?

Provide the site exposure, panel and support materials, coating requirement and applicable standard edition. Check evidence for the exact fastener variant and sample; a coating description or laboratory exposure duration alone does not establish project suitability.

What information is needed for a side-lap fixing?

Share the panel profile, thickness, overlap detail and panel supplier or engineer requirements. Confirm the fastener, spacing and function against that detail; do not substitute a side-lap fastener for the primary sheet-to-support connection.

Angebot anfordern

Senden Sie eine Zeichnung, Artikelnummer oder Projektbeschreibung für Ihre Anfrage.

Anfragen