หลังคา / ผนัง / เหล็ก
BUILDING ENVELOPE CONNECTION / FLEXIBLE MEMBRANE ROOFING

Flexible membrane roof fixing layers

A mechanically fixed membrane roof is a complete load path: membrane, plate or tube, insulation, deck, purlin and screw. Select the components as a system detail.

Cross-section showing membrane, insulation, deck, purlin, stress plate, tube and screw
CONNECTION LOGIC

What this connection has to do

Use this guide when the fastening must pass through a membrane and insulation build-up into a deck or purlin, with the roof-system supplier controlling the plate, tube and layout.

Use the connection detail before the product name. The same screw or bolt can be suitable in one layer and wrong in another. The build-up, support and installation method define the product family.
01 / BUILD-UP

Read the connection from the layers outward

These are the parts that control the fastener choice and the evidence needed for approval.

01

Membrane and seam

Identify the membrane, attachment detail, seam condition and the approved roof-system layout for the roof zone.

02

Plate or tube

The plate or tube spreads load into the membrane or insulation. Shape, diameter and stiffness are part of the tested detail.

03

Insulation and support

List insulation, cover board, deck, purlin and spacers. The screw must reach the support with the required engagement.

02 / SPECIFICATION

What to specify for this connection

Send these inputs with the drawing or site information so the proposed family can be checked against the actual assembly.

Selection questions

Each answer narrows the correct point, thread, head, material, washer or accessory. It also shows where a product-family label is not enough.

Ask for a connection review
Approved roof detailRoof-system name, membrane type, plate or tube model and fastening layout, including perimeter and corner zones
Layer build-upMembrane, insulation, cover board, vapour-control layer, spacers, deck and purlin thicknesses
FastenerPurlin-tail screw variant, length datum, point, diameter and tested support engagement
Load transferPull-out in the support, plate pull-through, seam strength and membrane behaviour are separate checks
EvidenceComplete assembly approval or test scope, site pull-out tests where required and installation records
03 / RANGE MAP

Product series and accessories

These families answer different jobs inside the connection. Open the family or product detail to confirm the exact offered variant.

04 / APPLICATION BOUNDARY

Where this product family stops

A clear boundary helps prevent a visually similar fastener from being substituted into the wrong connection.

05 / QUOTATION BRIEF

Send a complete connection brief

The more of this information is available, the faster the proposed family can be checked and quoted against the real installation.

Read the full application guide
01

Current roof-system attachment detail

02

Membrane, insulation and cover-board build-up

03

Deck/purlin material, grade and thickness

04

Screw, plate/tube, layout and site-test requirement

05

Approval scope, lot traceability and installation records

Have a drawing, section or site photo? Send the build-up and we can review the connection inputs with you.

Request a connection review